I don't think that the building codes anticipate block access to a gas meter caused by the temporary parking of vehicles so I don't think we'll find an explicit Prohibition in that regard. Brian You won't find such an explicit specific situation in the model nor the CA GAS CODES. In this example, the number that appears after "Q max" is both the meter capacity and indicative of the meter size. Get information on the Advanced Meter technology and features. Headquartered in Los Angeles, Southern California Gas Company is a subsidiary of Sempra, a Fortune 500 company based in San Diego. Rule No. GenRover Plus - 13000/23000 Watt Dual Fuel Portable Generator with Honda Engine. To convert Btu/Hr to CF/H divide the Btu/Hr by 1,000 (per PG&E delivery capacity), which is the number of Btu/Hr in a single cubic foot of natural gas . and NSTAR GAS & ELECTRIC INSTALLATION REQUIREMENTS [PDF] NSTAR. If your house has a gas meter that is not large enough, your gas-powered appliances may not be getting sufficient fuel. Depth includes 4 inches of bedding sand under gas line & 6 inches of sand shading over the gas line, & typical excavation trench width of 12 inches. Refer to the following sections in the Natural Gas Service Guidebook to understand what youll need to know for your next residential new construction project: Get help to potentially save time and money on residential new construction projects. Your bill is calculated on therms and not HCF. My . (NFGC 5.7.2.1). I am asking about a black iron gas line in a basement is this pipe allowed to touch a furnace single wall exhaust pipe, On 2020-01-07 by (mod) - gas meter clearances when building a porch over a gas meter. Every appliance has a date plate with this BTU rating. Meters shall not be minimum lateral distance from a gas line can I set a fence post? @Cb, ", @Marc, Today we are going to talk about the charges for Southern California Gas Company. On 2020-02-26 - by (mod) - my neighbor parks very close to my gas meter. Gas piping, provided it's properly installed, routed, protected from damage, and is the proper material, can run inside of buildings. If I close in the patio, do I have to move the line or can I just enclose it in the new room? (505) 222-9800 My residential gas meter is located outdoors, adjacent to my garage wall. All I had to do was have an above ground connection point. This is also called the Customer Charge, Readiness to Serve charge or Minimum charge. The model plumbing code (UPC) does discuss requirements for gas piping that your plumbing inspector might consider when looking at your installation as in your photo. an opening in the outside wall not less than 36 inches Really? To be conservative, 15% is added to the gas meters rated capacity to arrive at its maximum continuous capacity. Las Cruces, New Mexico 88001 Exception: Listed and labeled flush-mounted-type quick- disconnect devices and listed and labeled gas convenience outlets shall be installed in accordance with the manufacturer's installation instructions. Part-time. My natural gas service line currently runs along the wall of my house across my patio. Garry: Most rotary gas meters will have sizes of 175 to 275 CFH. If the La traduccin al espaol correspondiente no est disponible. All gas meters have internal moving parts that . Recently, i noticed my neighbor park his truck close to my gas meter with the tail pipe facing my meter. How close to the gas meter can i legally install a water heater? A fast food outlet or takeaway could use anywhere between 70 kW and 150 kW, and this is usually similar to a restaurant. why did jill and ryan divorce; sig p320 80 percent; take home pay calculator 2022; work capability assessment how long for decision 2021; socal gas meter sizes | . secondary service lines must conform to the following codes On 2021-05-12 Your analog meter should have 4 or 5 dials in a row along the top of its face. Gas Piping Clearance Distances by Inspectapedia Com Moderator. No surprise, you won't see "fence posts" listed as a gas piping obstruction or code detail in the model building codes. Outlets shall not be placed behind doors. Rebates and special programs are available for your gas construction project needs. These regulations require a three-foot clearance from indoor meters to sources of ignition, but have no comparable requirement when the meter is located outdoors. from my driveway this seems unsafe, Please see the article: CLEARANCE DISTANCES FOR AIR CONDITIONER / HEAT PUMP COMPRESSOR / CONDENSER UNITS. - PSE&G cited below. Thanks for the question, Steve. Application for non-residential new construction natural gas installation. Dryer 30,000 Btu/hFurnace 80,000 Btu/h Kitchen Range 50,000 Btu/hWater Heater 40,000 Btu/h. As an example, a gas meter with a 275 cf/h rating has a maximum continuous capacity of 385 cf/h. For example, on the standard rate of $0.16438 per day * 30 days = $4.93 for the minimum charge for the month. There are a lot of violations of this in Northern New Mexico. Local building code requirements for safe distances from a gas meter or gas meter vent vary, depending on where you live, and are also different between the U.S. and Canada. Common meter sizes range from 175 cf/h to 275 cf/h. A commercial building could use much more gas. This measure is taken from laboratory tests of a gas meter. Available at where oblique references are made to clearances. Excerpt General Details Housed in a compact aluminium case, the Model 750 is a slow revving high capacity gas meter. InspectAPedia tolerates no conflicts of interest. From what I've found in gas meter and electrical specifications from several utilities, a building wall can serve as a barrier wall when it's solid masonry; I would think that we'd care about the wall construction materials, and about how well any wall penetrations are sealed. On 2020-05-14 - by (mod) - How far from gas supply line to. I've seen lots of grills and other generators hooked up in the same fashion. How many feet max can be from your main gas line to a fixture, On 2021-12-09 " The trademarks used herein are the property of their respective owners. You're on the right page. All rights reserved. Likewise, installing an emergency standby generator will increase gas demand and may call for a split-meter system. All portions of a gas utility distribution system up to the outlet of the meter are regulated by 49 CFR Part 192, under the U.S. Department of Transportation. Recently noticed Camcast cable entering mother-in-laws house wrapped around the gas line. All rights reserved. The whole credit is applied as once since our system doesnt carry over credits. Let us know if you have more questions. what are the clearance requirements between a gas pool heater and electric A/C unit? [NFPA54: 7.1.1]. Watch out: be sure to see the article series beginning at Schools and nursing homes could use up to 1000 kilowatts at any given time or more. Metered usage 50 x Therm Factor of 1.035 = 50.75 therms billed. DS GAS CONNECTION | All Rights Reserved | Made by. Cha c sn phm trong gi hng. airbnb grand isle la Aquarium Silicone Sealant, Clear 10.2 fl. But most switches, panelboards, relays, and other devices that can create an arc when operated are treated as ignition sources. See GAS PIPING CLEARANCES, CODES & DEFECTS. So, for coastal areas of California, your winter baseline allocation would be 1.691 units per day * 30 days = 50.73 units for the month. by inspectapedia.com.moderator (mod) - How does a building wall count in gas meter clearance distance? I contacted the retired operations manager for the gas company and he said it was code to move it to the house. Those are needed. About Advanced Meter. A gas meter in a ceiling cavity sound questionable, unsafe, probably illegal to me, Eric.That location may violate the required working space, ventilation to the outdoors, and thus also be unsafe. Rockwell International was a major American manufacturing conglomerate involved in aircraft, the space industry, defense and commercial electronics, components in the automotive industry, printing presses, avionics and industrial products. Gas Appliance Technician - Los Angeles County. A fast food outlet or takeaway could use anywhere between 70 kW and 150 kW, and this is usually similar to a restaurant. CID - Santa Fe 26, Consumer Responsible for Equipment for Receiving and Utilizing Gas. The Southern California Gas Company warned customers Tuesday about an earthquake valve scam following the recent SoCal earthquakes. As well, most pool heaters have very tight inlet pressure requirements and, if the meter is too small . Nov 24, 2015. PG&E says we are responsible but it's not even near our house! Southern California Gas Company is a subsidiary of Sempra . If we did not go along with them, then they would not turn the gas back on. socal gas meter sizes. Maintaining the use of a wearless orbital valve, single convolution diaphragms, and lubrication-free bearings, the 400A delivers maximum initial and sustained accuracy. The standard daily rate is $0.16438 and the daily CARE rate is $0.131504. 5500 San Antonio Dr. Suite F Thank you for visiting Cook Electric at https://www.cookelectric.biz, Get the Right Size Gas Meter for Your Home, Top Reasons for Installing a Dedicated Circuit for Appliances, Smart Features for Your Homes Thermostat Part 2, Smart Features for Your Homes Thermostat Part 1, Get Protection From an Emergency Standby Generator, Future Proof Your Home With Top Electrical Trends Part 2. You may also submit this application if your project involves converting from propane/electric to natural gas and/or your plans include building an accessory dwelling unit (ADU). and electrical components (meter, service drop, etc). See what rebates and incentives are available to save money when installing efficient natural gas appliances. Measure as a direct, straight line from the nearest meter set or component to the nearest edge of the building feature "as if using a string". GilbertModel codes as well as your local building inspector will almost certainly require one or more protective bollards installed such that it becomes impossible to drive directly into the meter. Next up is the daily charge. The length of pipe from the gas meter to the most remote outlet (outlet A) is 60 feet. Perhaps I don't understand the situation correctly but it sounds to me as if the gas company is agreeing to do the expensive part of the repair which is moving the metre to where should be and replacing an underground pipe that was leaking. See details at PROTECTION BOLLARDS for MECHANICAL EQUIPMENT. Clothes dryer : 30. All gas meters will be placed With the addition of a 400kBTU/hr heater, most standard residential meters are not large enough. When the hand is between "9" and "0," then "9" is considered the lower number. Gas piping clearance underground to structure: We require a 3-foot minimum separation between natural gas and electric facilities. 1211.1.1 Clearances. GR rates are used to calculate your bill. Meter mounting device (meter base) locations, as per Rule 6-408 f), shall be in compliance with the requirements of the supply authority. The only time I see it causing a problem is if the meter is taken out under load causing an arc and the gas from the regulator is somehow contained in the area, but how can it be contained if it is outdoors? person disconnects the outlet of a gas service meter from the house piping , what must be done prior to turning on gas service meter ? socal gas meter sizes what is the hardest grade in school? It may be that you were describing sloppy work however. @Damon, It wasn't disclosed to us when we bought the house. This rate is calculated by the day so you would take whichever one is applicable to you and multiply it by the days in the meter read cycle. need to run electric line from breaker box to sub panel outside to entry spot in foundation there is a gas line already there can I run the enclosed wire next to gas line what would be the min distance from gas line? Then the connections are tested for leaks. Together, they produce a 4- or 5- digit reading. From the page above we know that opposite or another wall. Electricity and Gas Inspection Regulations (SOR/86-131) SoCalGasis a registered trademark of Southern California Gas Company. Refer to the following sections in the Natural Gas Service Guidebook to understand what youll need to know for your next project to modify existing natural gas service. You may also submit this application if your project involves replacing a SoCalGas meter with a larger capacity meter (meter upsize) due to the installation of additional natural gas appliances on your non-residential site. Providing professional electricians since 1988 in Maryland, Cook Electric is the company you can rely on for all your electrical service needs. I am a Realtor and I have not found anyone in DE who says a hose bibb within 2 feet of a Gas Meter is a problem meters and other sources of @Jross, your local building code inspector, plumbing inspector, and the gas company will all want to enforce gas meter clearance requirements; Part Time Cashier Bilingual - Spanish (Central, Commerce, Crenshaw, Inglewood, and South Gate) Los Angeles, CA. This is a mobile home park, and our units are close together. Few household appliances (tank water heaters, forced-air gas heaters, gas stovetops, etc) consume as much gas as a pool heater. We talked about daily charges, how tiers are calculated, what rates are used, the differences between standard and CARE rates, fees, rate blending, and the CA Climate credit for your Southern California Gas charges. The unthreaded portion of piping outlets shall extend not less than l inch (25 mm) through finished ceilings and walls and where extending through floors or outdoor patios and slabs, shall not be less than 2 inches (51 mm) above them. 192.353) (NFGC 5.7.2.3)Meters are to be located in ventilated spaces accessible CAN/CSA-Z662 SoCalGas and PG&E provide service to about 5.9 million and 4.3 million customers, respectively, while SDG&E provides service to over 800, 000 customers. First, the distance from the gas meter to appliances may have a bearing on whether you need a bigger meter, because gas pressure drops over distance traveled. When the rates change, we do not have the space to create two separate breakdowns to accommodate the different charges. Book your home inspection by calling 818-298-3405 or book online here. A tracer wire is usually not connected directly to the meter, though it can be. Does this mean that the water spigot needs to be two feet away? In addition to the gas meter clearance distances given in the page above, tell us who and where "DTE" is, (your country and city of location might help), and let's see if we can find DTE's own specifications for gas meter installations and clearance distances from various site features. There are a number of instances in the CSA B149.1 Natural gas and Propane Installation Code Honda Powered Generators. a 6 foot tall regulation cedar privacy fence is being built. As a related example that could address gas vs electrical installation safety details, an electric meter installation on an un-finished wall may not be approved by your local inspector. So Cal Gas - Gas Meter Relocation for Solar Installation - Porter Ranch SolarCity of Los Angeles requires gas meter to be 36 inches (3 feet) away from Main S. What to know before requesting meter set. Work with a licensed electrician for your safety and the best results. Meter Technician (Former Employee) - San Luis Obispo, CA - March 17, 2022. Bill, That's not a constraint I've seen, so as long as you're not obstructing the egress in any way I'd expect your code officer will be ok with the routing. 1. When I was hired by SoCalGas I was told I would receive a raise after 6 moths on the job. We keep an eye on this and so far it has not happened. Watch out: it's not clear in your photo but your gas delivery to the generator may need an additional gas pressure regulator to step down from the incoming pressure from the primary regulator at the meter. Questions have been asked regarding the specific types of electrical equipment covered by the Rule. gas meter is less then 3 ft from 2 windows, CLOTHES DRYER VENT CLEARANCES & TERMINATION, GAS METER CLEARANCE SPECIFICATIONS for ALBERTA, BGE GAS & ELECTRIC INSTALLATION SPECIFICATIONS, NSTAR GAS & ELECTRIC INSTALLATION REQUIREMENTS, INFORMATION BULLETIN NO: B-G5 051206 4, CLEARANCE TO METER REGULATOR VENTS, UNIFORM PLUMBING CODE CHAPTER 12 FUEL PIPING, NSTAR GAS & ELECTRIC INSTALLATION REQUIREMETNS, REQUIRED DISTANCE FROM GAS PIPES, LIQUID PROPANE Do not locate gas meter set assembly (MSA) under decks, doors or stairways 3' Electric Outlets 3' Door 3' 3' 3' 3' 3' 1' Soffit Vents Garage Doors Attic Vents Openable Windows Crawl Space or Garage Vents Appliance Vents or Air Intakes 3' Min 16" to 18" 3' 3' Relief Vent 26" to 28" Typical AC Condenser Diagram A . Just to be 100% clear.. the meter has to be 3' away from any door or window? Justin A lady just bought abandoned house next door. As shown in the figure below, the amount of natural gas (934 cubic feet per hour or CFH) that can be moved through a 100 ft long - 3/4-inch pipe (operated at 2 PSIG) would require a 2-inch diameter pipe when the same system is operated . Please attend a Public Participation Hearing (PPH) to provide the CPUC's Administrative Law Judge (Judge) with feedback as they oversee SoCalGas' 2024 General Rate Case (GRC) application for a rate increase. See PG&E GREEN BOOK ELECTRIC & GAS SERVICE REQUIREMENTS (TD-7001M) 20202021 [PDF] original source: https://www.pge.com/pge_global/common/pdfs/services/building-and-renovation/greenbook-manual-online/greenbook_manual_full.pdf, Also see this Watch out: the installation in your photo looks quite dangerous to me: unless your fittings include a quick-disconnect that reliably shuts off the gas supply and that is approved for your outdoor use, the presence of a valve at the gas meter that could be opened to dump an endless flow of natural gas at the building risks fire or explosion - when the flexible gas hose is disconnected or should the hose be damaged and leak. Total charges for usage equal $88.15. What's the minimum lateral distance from a gas line can I set a fence post? With this specification met, there are no clearance distance requirements for building features located around the corner from the gas meter. Gas company informed us and her about the clearance issue for meters . This issue has arisen in a Home Inspection that took place in Sussex County, DE at the home of my Seller Clients. There's not a single generic right answer to your question as phrased. When we connect solar to the grid or do a service upgrade they want us to comply most times, although a lot of time it is "grandfathered in" as well. board on an adjacent wall, https://up.codes/viewer/california/ca-plumbing-code-2016/chapter/12/fuel-gas-piping#12. high by 36 inches wide. Santa Fe, New Mexico 87505 The article above gives gas meter clearance distances from model building or mechanical codes and from codes adopted by a range of U.S. or Canadian states or Provinces - it's not simply personal preference. Another fun fact about meter reads is that they should not vary more than three days in either direction from cycle to cycle. How far does a meter need to be away from any intake in a home, Anon: I am also tapping into an exterior outlet to run electrical to the outdoor grill kitchen. Can anybody answer my question please, Sure David, you can see the clearance distances to Windows and Doors in the tables above on this page, my gas meter is less then 3 ft from 2 windows is just over 3 ft from my door is located in driveway right next to house where i park my truck is prob 2 ft from it is any of this legal, On 2020-11-04 CAN/CSA-B149.1 We have a Tenant who parked his boat between the fence and the house leaving only about 18 inches clearance from the gas meter. Sure, the clearances are given in the article above. 1998 - document.write(new Date().getFullYear())Southern California Gas Company. Regulators installed on the exterior of the building shall be approved for outdoor installation. A gasfitter sizes a rotary gas meter depending on the gas volume flow rate. All of these gas regulators are outdoors and though the utility has a rule about their meters needing to be 3 feet from the regulator, the enforcement is spotty, especially in existing homes. How close can a electric mater be a gas meter. Anything outside of that is considered unpredictable and hard to budget for. The PPP fee is $0.10060 per therm and the SRF is $0.00166 per therm. BACKUP ELECTRICAL GENERATORS because there are critical life-safety hazards when using a backup generator. The simplest method for calculating demand is adding up the British thermal units/hour (Btu/h) ratings of all the gas appliances in a home. At higher altitudes, you might have a metered usage of 50, but be billed for 51.75 therms with a factor of 1.035. Our Comment Box is provided by Countable Web Productions countable.ca, Click to Show or Hide Citations & References, Defects, installation & inspection points for gas meters. found by searching InspectApedia.com for "mobile home codes" But your *local* building code compliance inspector is the final legal authority on clearance distances for gas (what - piping, meters, appliances?) A meter is capable of providing gas at a level greater than its rated capacity. It does sound a bit unusual for a gas meter serving only your home to be located such a great distance away. You can browse through all 39 jobs SoCalGas has to offer. For example, 80 units * 0.997 therm factor = 79.76. (505) 476-4700 The Alberta Gas Code Regulations, Gas Meter Clearances, BC, British Columbia, Canada, courtesy of Canadian Chimney, 521 Short Close Ladysmith, BC V9G 1A7 Canada, (250)800-2251 https://www.canadianchimney.com/, For BC, Canada gas meter clearances also see It also covers the piping to the outside water for his unit. My meter says it's rated for 250 CFH @ 0.5" diff. Indeed, however, the building and mechanical code details may vary by state. On 2021-08-02 When the hand looks as though it is DIRECTLY on the number, look at the dial to the right. The pictures are useful for utility checks, or when everyones usage and billing is reviewed. Gas rates change every month so you will never get a perfect match to the rate sheets. They should be read between 26 and 35 days each cycle. These Gas Meters Feature: Measures propane or natural gas in cubic feet. GR Sheet 2 RESIDENTIAL SERVICE (Includes GR, GR-C and GT-R Rates) (Continued) (Continued) (TO BE INSERTED BY UTILITY) ISSUED BY (TO BE INSERTED BY CAL. The first dial is the first digit in the reading, the second dial is the second digit, and so on. The baseline allocation is determined by zone and number of days in the billing cycle, much like In my OPINION, if we find an unsafe or poor construction practice it usually makes sense to correct it first and worry about grandfathering second. It is possible that no one will require your neighbour to do a thing about the location of her gas meter hookup point until she or someone new wants to actually have gas service (and thus a meter) installed at the building. receptacles, switches, meter base plug in transfer devices, meter base plug in devices with an internal service air conditioning units, and related disconnecting means. More examples are below, and all of these are included in our citations given in the article above. This Information Bulletin summarizes the In this article series on gas meters, controls & piping, we provide descriptions and photographs of unsafe gas piping, indications of unsafe or improperly operating gas appliances, gas meters, and other gas installation defects. Schedule G-NGVR, Natural Gas Service for Home Refueling of Motor Vehicles (Includes G-NGVR, G-NGVRC and GT-NGVR Rates) Schedule GL, Street and Outdoor Lighting Gas Svc; Schedule G-10, Core Commercial and Industrial Service (Includes GN-10, GN-10C and GT-10 Rates) Schedule G-AC, Core A/C Svc for Commercial/Industrial (Includes G-AC, G-ACC and GT . the front of an electric panel normal cubic meters (Nm3) - 1 cubic meter at 20C at 101.325 kPa. Electrical equipment that can serve as a source of ignition is defined as an ignition source if it creates an arc or spark during operation. The line will come off the meter and run parallel to the house. 59411-G Schedule No. Electrical equipment is a source of ignition if it creates an arc or spark during operation. "There must be a minimum of three feet (0.9m) separation between any part of the gas meter/regulation installation and any sources of ignition (i.e. Also see A separate table titled Ask your building inspector for an opinion and let me know what you're told. Rule No. M100 indicates a U100 meter. Thank You Dj. GAS METER CLEARANCE DISTANCES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice. This is done independent of the generator installation, and scheduled and paid (if there's a charge) for directly . I have not found a national gas code discussion of "temporary" gas piping connection valves and shutoffs, and I agree that there are plenty of outdoor connections to natural gas piping. When it does, we will wait until it hits the master meter bill before passing it on to residents. Can I get the codes and distances for gas and electric box in a mobile home park. Similar to what many gas provider companies install - one piece body with security seals to indicate tampering. No two sites are the same. Here is the link to the latest The Gas Meter Guard is 9 x 7 x 4 1/2 inches and is meant to cover the clear or grey plastic box mounted on the metal gas meter housing and is designed to adjust to fit almost all sizes of gas and water smart meters. Line gas pressure regulators shall be listed as complying with ANSI Z21.80. Standard and CARE. In 2018, California gas utilities forecasted that they would deliver about 4740 million cubic feet per day . Please take a look, Marie. They only charge $350 when they have to change the meter to 2psi pressure and put in regulators further downstream to bring the pressure back to the typical 7" wc (=0.25 psi) the appliances use. Albuquerque, New Mexico 87109 Electrical will be housed inside conduit. I would be happy with that solution. Continue reading at GAS PIPING CLEARANCES, CODES & DEFECTS, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX. but in the table I recommended you'll find Its service area encompasses 23,000 sq mi (60,000 km 2) of diverse terrain throughout most of Central and Southern California, from just south of Sanger to the Mexican border. Gas Piping Clearance Distances 2019 Ardent Billing. Thanks. - minimum lateral distance from a gas line can I set a fence post? 6 inches is the standard clearance between meter bottom and grade level Permits for construction must be secured before completing this application. In, Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. Enbridge, serving: Illinois, Iowa, Nebraska, South Dakota, USA, EC Magazine, "Code Questions & Answers", (February 2000 Q&A discussing August 1999 magazine issue) Electrical Contractor Magazine, 3 Bethesda Metro Center, Suite 1100 Bethesda, MD 20814 USA Tel: 301.657.3110 Website: http://www.ecmag.com/. I was told by a friend that we should not have any temporary connections outside the house. ErnieIn the article above see the details about gas meter clearances to electrical components in the table titledGas Piping Clearance DistancesYou'll see that ordinary circuit wiring isn't considered an ignition source but panels are. There is also misunderstanding about the term 'source of ignition.' Including to doorways. @jerry, Using the "distance to sources of ignition" table in the article above I'd figure 3 ft. PLUS any additional working space required by either the meter or the water heater.Here's an excerpt;At least 3 feet, per NEC 110-26 & NFPA 54-National Fuel Gas Code for premises-owned gas meters. minimum clearances specified in this table must be maintained. In addition, you and your neighbour should review GAS METER PROTECTION BOLLARDS I live in Oklahoma. We also provide an ARTICLE INDEX for this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need. That's not a specification that I've been able to find, John. The following applications and cost estimator tools on SoCalGas' Builder Services page will be undergoing maintenance on Wednesday, February 1, 2023, from 5 to 7 PM PST: Application for residential new construction natural gas installation. The second is the peak demand for gas you require at any given moment. Below are examples of ratings. I was not able to find a specific date for New Mexico's first building code adoption. Meter bases, conventional mechanical meters and conventional smart meters are not a source of ignition, and are permitted to be located within 1 metre of a natural gas discharge opening and 3 metres of a propane gas discharge opening.
Dribble Drive Actions, Latent Print Sequential Processing Chart, Articles S